The Uniform Magnetic Field for NMR is a permanent magnet for nuclear magnetic resonance (NMR) technology. Its high processing precision, good stability, and uniform magnetic field have many applications in scientific research, medical treatment, and industry.
Product Characteristics
1. High-precision processing: The Uniform Magnetic Field for NMR adopts advanced processing technology and equipment to ensure that every detail of the permanent magnet reaches extremely high precision. This high-precision machining ensures the uniformity and stability of the magnetic field distribution and provides a reliable guarantee for NMR experiments.
2. Excellent stability: This product's design fully considers the need for magnetic field stability and achieves long-term stable magnetic field output by optimizing the structure and material selection of permanent magnets. This stability is particularly important for NMR experiments that require long periods of continuous operation.
3. Magnetic Field uniformity: The core advantage of The Uniform Magnetic Field for NMR is the uniformity of its magnetic field. We use unique magnetic field design technology, and advanced magnetic field measurement means to ensure that the uniformity of the magnetic field in a uniform area reaches 1 ~ 5 *10⁻⁴. This high degree of uniformity makes NMR lines clearer and more high-resolution, providing researchers with more accurate data support.
Parameters of uniform magnetic field for NMR
|
Model |
Pole Face Dia. (mm) |
Air gap (mm) |
Center magnetic field(T) |
Size of uniform field (mm) |
Shape |
Weight (Kg) |
|
NMR 7014-03 |
70 |
14 |
0.3 |
Φ6*3 |
100 x 124 x 130 |
8.2 |
|
NMR 7014-066 |
70 |
14 |
0.66 |
Φ6*3 |
100 x 124 x 130 |
10 |
|
NMR 10020-03 |
100 |
20 |
0.3 |
Φ8*5 |
130 x 136 x 166 |
15 |
|
NMR 10020-05 |
100 |
20 |
0.5 |
Φ8*5 |
130 x 136 x 166 |
18 |
|
NMR 10030-05 |
100 |
30 |
0.5 |
Φ6*5 |
150 x 130 x 134 |
21 |
|
NMR 14025-03 |
140 |
25 |
0.3 |
Φ10*7 |
170 x 145 x 210 |
25 |
|
NMR 14025-058 |
140 |
25 |
0.58 |
Φ10*7 |
170 x 145 x 210 |
30 |
|
NMR 14030-037 |
140 |
30 |
0.37 |
Φ8*8 |
170 x 158 x 210 |
30 |
|
NMR 5030-045 |
50 |
30 |
0.45 |
Φ6*3 |
140 x 200 x 160 |
8.2 |
|
NMR 470120-027 |
470 |
120 |
0.27 |
Φ50*30 |
440 x 640 x 600 |
780 |
|
NMR 15030-04 |
150 |
30 |
0.4 |
Φ10*8 |
230 x 180 x 170 |
40 |
|
NMR 6525-09 |
65 |
25 |
0.9 |
Φ8*5 |
285 x 320 x 320 |
72 |
|
Uniformity: 5*10⁻4 |
||||||
Deliver, shipping and serving
In a competitive logistics environment, providing efficient and reliable transportation solutions is critical to earning and maintaining customer trust. To this end, we firmly adhere to the customer-centric policy, the use of sea, air, and other comprehensive modes of transportation, and tailored logistics solutions for each customer to meet the individual needs of each customer. Our experienced logistics team uses expertise to develop transportation plans based on the specific attributes of the goods and their intended destination. We are relentlessly pursuing perfect service to ensure every shipment arrives on time, safely, and error-free.



FAQ
Question 1: How can The Uniform Magnetic Field for NMR achieve such high uniformity?
The Uniform Magnetic Field for NMR uses advanced magnetic field design and optimization techniques, combined with precision machining and assembly processes, to achieve such high magnetic field uniformity. Our magnetic field design team ensures that the magnetic field is evenly distributed in the target area and reduces magnetic field distortion through accurate magnetic field calculations and simulations. At the same time, we strictly control the quality and assembly accuracy of the permanent magnet, further improving the uniformity of the magnetic field. This highly uniform magnetic field provides more accurate and reliable data support for NMR experiments.
Question 2: How can the stability of the Uniform Magnetic Field for NMR be guaranteed?
First, we use high-quality permanent magnet materials to ensure the long-term stability of the magnetic field.
Second, we use advanced magnetic field stabilization technologies, such as magnetic field locking systems and temperature control systems, to eliminate the influence of external interference and temperature changes on the magnetic field. In addition, we regularly calibrate and maintain the magnetic field to ensure that it is always in optimal condition.
Question 3: In which NMR experimental applications does The Uniform Magnetic Field for NMR have advantages?
First, due to its highly uniform magnetic field, the product performs well in NMR experiments that require high resolution and sensitivity, such as the structure analysis of biological macromolecules, drug screening, and other fields.
Secondly, our products have excellent magnetic field stability and are suitable for NMR experiments that run continuously over long periods of time, such as protein dynamics studies. In addition, we offer a variety of magnetic field strength and size options to meet different experimental needs.
Whether in research laboratories or industrial production, The Uniform Magnetic Field for NMR provides efficient and reliable NMR experimental solutions.












