Axial Permanent Magnets Performance Test Report

 

Introduction

 

1. Test purpose

Through the analysis of the test results, the evaluation of the product performance is obtained;
Evaluate whether the test product meets the technical requirements;
Provide reference data for product design and after-sales service, and provide a strong basis for leaving the factory.

 

2. Basic information

 

Product Name:
Axial water-cooled permanent magnet
Product model: Customized
Test time: Jan. 14, 2024

 

3. Testing environment

 

The detection environment is closer to the actual environmental conditions used by the user, including factors such as lead wire length and ambient temperature. The time is selected in the time interval where the fluctuation of the geomagnetic field is small. Before the test, the instruments required for the test were turned on and warmed up in advance and the measurement environment was recorded, as shown in Table 1.

 

Measurement environment
Environment temperature Product initial temperature Lead length Environmental magnetic field
8.0℃ 8.0℃ - 0~30000nT
Table 1 Measurement environment data

 

Magnetic field parameter test

 

1. Using the device

DX-180 Gauss Meter

 

2. Magnetic field measurement

 

This product uses the following measurement methods:
Fixed-point measurement: measure the magnetic field at the target point

 

Magnetic field strength
Air Gap Display current (A) Display voltage Voltage (V) Magnetic field
strength(Gs)
0,100,0 - - -3758.8
0,90,0 - - -3970.4
0,80,0 - - -3561.5
0,70,0 - - -2475.4
0,60,0 - - -894.2
0,50,0 - - 1000.6
0,40,0 - - 3115.9
0,30,0 - - 5349.9
0,20,0 - - 7426.3
0,10,0 - - 8922.1
0,0,0 - - 9474.6
0,-10,0 - - 8952.8
0,-20,0 - - 7475.3
0,-30,0 - - 5390.6
0,-40,0 - - 3125.9
0,-50,0 - - 966.6
0,-60,0 - - -956.8
0,-70,0 - - -2528.3
0,-80,0 - - -3549.8
0,-90,0 - - -3877.1
0,-100,0 - - -3620.2
Table 2 Magnetic field strength data

 

The product's magnetic field and electrical performance meet the requirements of the corresponding technical parameters. The product's final performance is subject to this document.