Adjustable Magnetic Field Permanent Magnet Performance Test Report

Oct 08, 2024

Leave a message

Adjustable Magnetic Field Permanent Magnet Performance test report
Introduction
1. Test purpose
Through the analysis of the test results, the evaluation of the product performance is obtained;
Evaluate whether the test product meets the technical requirements;
Provide reference data for product design and after-sales service, and provide a strong basis for leaving the factory.
2. Basic information
Product Name:
Adjustable Magnetic Field Permanent Magnet
Product model: Customized
Test time: June 26, 2023
3. Testing environment
The detection environment is closer to the actual environmental conditions used by the user, including factors such as lead wire length and ambient temperature. The time is selected in the time interval where the fluctuation of the geomagnetic field is small. Before the test, the instruments required for the test were turned on and warmed up in advance and the measurement environment was recorded, as shown in Table 1.
Measurement environment
Environment temperature Product initial temperature Lead length Environmental magnetic field
30.0℃ 30.0℃ - 0~30000nT
Table 1 Measurement environment data
 
Magnetic field parameter test
1. Using the device
DX-180 Gauss Meter
2. Magnetic field measurement
This product uses the following measurement methods:
Fixed-point measurement: measure the magnetic field at the target point
Magnetic field strength
Air Gap Display current (A) Display voltage Voltage (V) Magnetic field
strength(T)
10mmGap - - 0.815
100mmGap - - 0.232
Table 2 Magnetic field strength data
 
The magnetic field and electrical performance of the product meet the requirements of the corresponding technical parameters. The final performance of the product is subject to this document.